125 Amp Sub Panel Wire Size
A 125 Amp sub panel requires special attention when it comes to wiring. The size of the wire will depend on the distance from the main panel to the subpanel. It is important to choose the right wire size to ensure that the subpanel is properly supplied with power and that no damage is done to the wiring or connected appliances. Knowing the right wire size for a 125 Amp subpanel is essential for any DIY homeowner or builder.
Understanding Wire Gauge and Amperage Ratings
Before selecting the right wire size for a 125 Amp subpanel, it is important to understand the basics of wire gauge and amperage ratings. Wire gauge is a measure of the size of the wire, which is determined by its diameter and number of strands in the conductor. The higher the gauge number, the smaller the wire. Amperage is a measure of the electrical current that the wire can safely handle. A higher amperage rating means that the wire can handle a higher current. The National Electric Code (NEC) stipulates that a 125 Amp subpanel should be wired with at least #8 AWG (American Wire Gauge) wire.
Choosing the Right Wire Size for a 125 Amp Subpanel
When choosing the right wire size for a 125 Amp subpanel, the most important factor to consider is the distance from the main panel to the subpanel. The NEC specifies that #8 AWG wire should be used for a subpanel that is located up to 50 feet away from the main panel. For subpanels located more than 50 feet from the main panel, #6 AWG wire should be used. The NEC also requires that the wire be protected by an appropriate circuit breaker or fuse in the main panel.
Calculating Voltage Drop for a 125 Amp Subpanel
Another factor to consider when selecting the right wire size for a 125 Amp subpanel is voltage drop. This is the amount of voltage lost as the current passes through the wire. Voltage drop should not exceed 3% for most applications. The NEC provides tables that can be used to calculate the voltage drop for a given wire size and distance. It is important to use the correct wire size to ensure that the voltage drop is within acceptable limits.
Wire Protection for a 125 Amp Subpanel
The NEC also requires that the wire used to wire a 125 Amp subpanel be protected against physical damage. This can be done by using conduit or cable trays. Conduit is a type of piping that is used to protect the wire from physical damage and to prevent moisture from entering the wiring. Cable trays are another type of protection that can be used to route the wiring and protect it from physical damage.
Installing the Subpanel for a 125 Amp Subpanel
Once the wire size has been selected and the protection installed, the next step is to install the subpanel itself. The NEC requires that the subpanel be installed in a dry, easily accessible location. It should also be installed in a location that is not subject to flooding or other sources of water damage. The subpanel should be mounted at least 18 inches above the floor and should be firmly secured to the wall or floor.
Conclusion
Choosing the right wire size for a 125 Amp subpanel is essential for any DIY homeowner or builder. It is important to understand the basics of wire gauge and amperage ratings before selecting the wire size. The NEC provides tables to help with calculating the voltage drop for a given wire size and distance. It is also important to protect the wire from physical damage and to install the subpanel in a dry, easily accessible location. Following these guidelines will ensure that the subpanel is properly supplied with power and that no damage is done to the wiring or connected appliances.